← Product Catalogue
Brackish Water RO8040Fouling Resistant

Brackish 8040 — High Performance / Fouling Resistant

HMBW-34-400-FR

High-performance industrial brackish water reverse osmosis element engineered for challenging feed conditions, improved fouling resistance and stable long-term operation.

Key Performance

Active Area

400

ft²

Permeate Flow

11,500

GPD

Salt Rejection

99.7%

Stabilised

Feed Spacer

34

mil

Performance values are based on Hi-Tech's specified element test conditions and should be considered alongside actual feed-water and system operating conditions.

Technical Data

Performance specifications.

Key performance values for the HMBW-34-400-FR high-performance industrial brackish-water reverse osmosis element.

Active Area

400 ft²

37.2 m²

Permeate Flow

11,500 GPD

43.53 m³/day

Stabilised Salt Rejection

99.7%

Nominal performance

Operating Pressure

150 psi

10.3 bar

Feed Spacer

34 mil

Fouling-resistant configuration

Element Format

8040

8 inch × 40 inch

Operating Envelope

Operating limits.

System design and operation should follow the current manufacturer datasheet and project-specific engineering requirements.

Maximum Operating Temperature

45°C

113°F

Maximum Operating Pressure

600 psi

41 bar

Maximum Feed Flow Rate

75 gpm

409 L/min

pH Range

2–11

1–13 during cleaning

Maximum Feed SDI

5

SDI

Free Chlorine Tolerance

< 0.1 ppm

Pretreatment recommended

Feed Water Turbidity

1.0 NTU

Maximum

Maximum Pressure Drop

15 psi

1.0 bar per element

Physical Specifications

Standard 8040 geometry.

Designed for compatibility with standard industrial 8-inch reverse osmosis pressure vessels.

Weight

10.60 kg

23.37 lbs

Length

40 in

1016 mm

Diameter

7.9 in

201 mm

Permeate Tube

1.125 in

29 mm

Key Features

Engineered to resist fouling.

Dry-shipped for extended shelf life

100% vacuum leak tested for structural integrity

Compatible with standard RO housings

Advanced feed spacer design to minimise fouling

Optimised flow dynamics to reduce pressure drop

Enhanced resistance to organic and particulate fouling

Durable for harsh feed-water conditions

Main Benefits

Less fouling. More uptime.

Reduced fouling and cleaning frequency

Improved system uptime

Lower chemical usage

Stable long-term performance

Applications

Built for challenging industrial feed water.

Wastewater reuse systems

Effluent treatment plants

High-organic load water streams

ZLD / MLD systems

Industrial recycling processes

Equivalent Matching

Replacing a fouling-resistant membrane?

Compare HMBW-34-400-FR against equivalent models from major membrane manufacturers.

Compare HMBW-34-400-FR

Technical Documentation

Need the complete technical sheet?

Access full manufacturer performance data, operating limits, dimensions and technical notes through the datasheet library.

View Datasheet